Opens in a new tab

Colocation data center space, sized to your servers.

Colocation means renting space, power, cooling and connectivity in a data centre for servers you own. Amanah Tech runs colocation at 151 Front Street West, from a single rack unit to a full rack.

An open server cabinet lit red from inside, beside a row of closed cabinets

Every way to rent space.

Colocation at Amanah starts at $149/mo CAD per U, with 1 Gbps unmetered bandwidth, a /29 IPv4 subnet and TorIX access in every plan. Prices are in Canadian dollars a month; pay annually and save 10%. Compare private racks, see every price or read about colocation in Toronto.

Shared rack

A few servers, priced by the U.

$149per U a month

  • 1 U of rack space in a shared cabinet
  • 24″ W × 42″ D × 1.75″ H
  • Escorted access
  • 1A at 110V
  • 1 Gbps uplink
  • /29 subnet
  • Unmetered bandwidth
See the shared rack

Quarter rack Most popular

Your own door, with room to grow.

$749a month

  • 10 U lockable rack space
  • 24″ W × 42″ D × 19.25″ H
  • Unescorted access, any hour
  • 20A at 110V
  • 1 Gbps uplink
  • /29 subnet
  • Unmetered bandwidth
See the quarter rack

Half rack

Half a cabinet for a growing stack.

$1,299a month

  • 21 U lockable rack space
  • 24″ W × 42″ D × 36.75″ H
  • Unescorted access, any hour
  • 20A at 110V
  • 1 Gbps uplink
  • /29 subnet
  • Unmetered bandwidth
See the half rack

Full rack

The whole cabinet for a full stack.

$1,999a month

  • 44 U lockable rack space
  • 24″ W × 42″ D × 77″ H
  • Unescorted access, any hour
  • 2 × 20A at 110V
  • 1 Gbps uplink
  • /29 subnet
  • Unmetered bandwidth
See the full rack

Infrastructure behind every plan.

One U or a full rack, every plan sits in the same building at 151 Front Street West, on the same power, cooling and team.

Space

1 to 44 U

From one U in a shared cabinet to the whole cabinet, 24″ wide and 42″ deep.

1 U10 U21 U44 U

Power

2.2 kW

Included on quarter and half racks, and 4.4 kW on a full rack, behind dual utility feeds, diesel generators and an N+1 UPS.

Cooling

Deep lake

Air cooled with chilled water from Enwave’s deep lake system, drawn from Lake Ontario.

Access

Any hour

Unescorted on quarter, half and full racks. Shared rack visits are escorted.

24/7

Power upgradesBook a tour

Connectivity.

Your rack sits in the building where Canadian networks meet, one cross connect from the carriers, backed by a 100% network uptime SLA.

Multihoming

Two paths

Start on Amanah’s network, AS32489, with a 1 Gbps unmetered uplink and a /29. Add a carrier in the building as your second path.

Cross connects

1 to 2 days

A dedicated cable from your rack to Beanfield, Cogent, Zayo, NetActuate, TorIX or a cloud on-ramp. No cap.

In the building

400+

Networks under the same roof as your rack, one cross connect away.

Peering and fibre

100G

100G peering on TorIX. Four diverse fibre entries into the building.

BGP multihoming, explainedCross connectsThe network

Security at every door.

Audited, access controlled and locked, with the report your auditors will ask for.

SOC 2 audit

Type II audited

SOC 2 Type II audited. The report is in our Trust Center, ready for your auditors.

Access control

Every door

Verkada access control into the data hall, then your own lockable door on quarter, half and full racks.

Canadian-owned

Never acquired

Canadian-owned since 2001. Your servers stay in Toronto.

Privacy law

PIPEDA, PHIPA

Compliant with both, including Ontario’s rules for health information.

Security at 151 Front Street WestTrust CenterWhat SOC 2 Type II colocation means

Upgrade without moving buildings.

Start with one server in a shared rack. Move to a quarter, half or full rack when you need the room, with the same network, the same team and no migration between facilities.

How much rack space do your servers need?

2
U of rack space

Shared rackfrom $298CAD a month
Space
2 U in a shared cabinet
Power
2A at 110V, about 220 W
Access
Escorted

Priced by the U. Past 5 U, a quarter rack costs less.

Your written quote confirms the final price.

  • Your servers
  • Room to grow in your space
  • Other customers

From quote to move-in day.

What happens between your first message and your servers running in the rack.

  1. Today

    Tell us your U count, power draw and start date, through the quote form or sales on ext. 1.

  2. Same business day

    Your written quote, with the monthly price in Canadian dollars.

  3. After you sign

    Your rack is ready for your equipment by the next business day. Bring your servers, or ship them and have our remote hands team rack and cable them.

  4. From then on

    Tickets, remote hands requests and cross connects go through the customer portal.

Racks that draw more power.

For dense servers and GPUs. Each is planned with you and priced by quote: tell us the kW per rack, the number of racks and your start date.

30 kWmaximum per rack

Full rack, included4.4 kW
High-density rack, up to30 kW
Air cooled with chilled water from Enwave’s deep lake system, the same as every other rack.

High-density colocation

High-density colocation at Amanah means up to 30 kW per rack, air cooled with chilled water from Enwave’s deep lake system. That is more than six times the 4.4 kW included with a full rack.

Plan a dense rack

AI and GPU colocation

Run an inference cluster or a single GPU rack without building your own facility. Our remote hands team racks and cables it, and you peer on TorIX at 100G in the same building.

Plan a GPU deployment

Colocation or cloud?

Colocation usually costs less than cloud for steady workloads you run every day, for traffic-heavy services that pay cloud egress fees, and for hardware you already own. Cloud is the better fit for spiky or short-lived workloads.

Your workload Colocation Cloud
The load runs all day, every day Better fit
Egress fees drive the bill Better fit
You own the servers already Better fit
Demand spikes and falls Better fit
The project is short-lived Better fit
You need many regions Better fit

Need more than a rack?

Need one boundary around several racks, or a room of your own? It is planned with you and priced by quote.

Private cage colocation

Your racks behind a mesh cage of your own, for teams whose auditors want physical separation.

Private suites

A partitioned suite of your own for larger deployments, with power planned per rack, up to 30 kW.

Just need two or three racks? Each one is added at the standard rates, in the same building.

Contact us
What is the difference between colocation and renting a server?

With colocation you own the hardware and we house it, power it, cool it and connect it. If you would rather not buy servers, we supply them in the same building as dedicated servers, on their own or alongside your colocation.

How much rack space do I need?

Count the rack units your servers take up; one U is 1.75″ tall. For a few servers, a shared rack priced by the U is the simplest start. Past 5 U, a quarter rack costs less and gives you your own lockable door. Find your size shows the plan for your U count.

What can 1A or 20A of power run?

At 110V, 1A is about 110 W and 20A is about 2.2 kW. A shared rack includes 1A per U; quarter and half racks include 20A, and a full rack includes two 20A circuits, about 4.4 kW. Add up what your servers draw under load, not the rating on the power supply. If you need more, power upgrades are on the Pricing page, and dense racks go up to 30 kW.

Why does colocation cost what it does?

The monthly price pays for the space, the power and cooling, physical security, the bandwidth in your plan and the people who run the building. Our prices are published, so you can see what each size costs before you call.

How do I get my servers into the rack?

Bring them in yourself, or ship them to us and our remote hands team racks and cables them. Your rack is ready for your equipment by the next business day after you sign.

Can I start small and grow?

Yes. Start with one server in a shared rack, then move to a quarter, half or full rack in the same building, on the same network, with the same team.

What if I need more than a full rack?

For several racks, we plan a private cage or a private suite with you, priced by quote. Power is planned per rack, up to 30 kW. Tell us what you need and we plan it with you.

Start with one U.
Grow to a full rack.

Tell us your U count and power draw, and we’ll size the right plan with you.