Shared rack
A few servers, priced by the U.
$149per U a month
- 1 U of rack space in a shared cabinet
- 24″ W × 42″ D × 1.75″ H
- Escorted access
- 1A at 110V
- 1 Gbps uplink
- /29 subnet
- Unmetered bandwidth
Colocation means renting space, power, cooling and connectivity in a data centre for servers you own. Amanah Tech runs colocation at 151 Front Street West, from a single rack unit to a full rack.

Colocation at Amanah starts at $149/mo CAD per U, with 1 Gbps unmetered bandwidth, a /29 IPv4 subnet and TorIX access in every plan. Prices are in Canadian dollars a month; pay annually and save 10%. Compare private racks, see every price or read about colocation in Toronto.
A few servers, priced by the U.
$149per U a month
Your own door, with room to grow.
$749a month
Half a cabinet for a growing stack.
$1,299a month
The whole cabinet for a full stack.
$1,999a month
One U or a full rack, every plan sits in the same building at 151 Front Street West, on the same power, cooling and team.
1 to 44 U
From one U in a shared cabinet to the whole cabinet, 24″ wide and 42″ deep.
2.2 kW
Included on quarter and half racks, and 4.4 kW on a full rack, behind dual utility feeds, diesel generators and an N+1 UPS.
Deep lake
Air cooled with chilled water from Enwave’s deep lake system, drawn from Lake Ontario.
Any hour
Unescorted on quarter, half and full racks. Shared rack visits are escorted.
Your rack sits in the building where Canadian networks meet, one cross connect from the carriers, backed by a 100% network uptime SLA.
Two paths
Start on Amanah’s network, AS32489, with a 1 Gbps unmetered uplink and a /29. Add a carrier in the building as your second path.
1 to 2 days
A dedicated cable from your rack to Beanfield, Cogent, Zayo, NetActuate, TorIX or a cloud on-ramp. No cap.
400+
Networks under the same roof as your rack, one cross connect away.
100G
100G peering on TorIX. Four diverse fibre entries into the building.
Audited, access controlled and locked, with the report your auditors will ask for.
Type II audited
SOC 2 Type II audited. The report is in our Trust Center, ready for your auditors.
Every door
Verkada access control into the data hall, then your own lockable door on quarter, half and full racks.
Never acquired
Canadian-owned since 2001. Your servers stay in Toronto.
PIPEDA, PHIPA
Compliant with both, including Ontario’s rules for health information.
Security at 151 Front Street WestTrust CenterWhat SOC 2 Type II colocation means
Start with one server in a shared rack. Move to a quarter, half or full rack when you need the room, with the same network, the same team and no migration between facilities.
How much rack space do your servers need?
Priced by the U. Past 5 U, a quarter rack costs less.
Your written quote confirms the final price.
What happens between your first message and your servers running in the rack.
Tell us your U count, power draw and start date, through the quote form or sales on ext. 1.
Your written quote, with the monthly price in Canadian dollars.
Your rack is ready for your equipment by the next business day. Bring your servers, or ship them and have our remote hands team rack and cable them.
Tickets, remote hands requests and cross connects go through the customer portal.
For dense servers and GPUs. Each is planned with you and priced by quote: tell us the kW per rack, the number of racks and your start date.
30 kWmaximum per rack
High-density colocation at Amanah means up to 30 kW per rack, air cooled with chilled water from Enwave’s deep lake system. That is more than six times the 4.4 kW included with a full rack.
Plan a dense rackRun an inference cluster or a single GPU rack without building your own facility. Our remote hands team racks and cables it, and you peer on TorIX at 100G in the same building.
Plan a GPU deploymentColocation usually costs less than cloud for steady workloads you run every day, for traffic-heavy services that pay cloud egress fees, and for hardware you already own. Cloud is the better fit for spiky or short-lived workloads.
| Your workload | Colocation | Cloud |
|---|---|---|
| The load runs all day, every day | Better fit | |
| Egress fees drive the bill | Better fit | |
| You own the servers already | Better fit | |
| Demand spikes and falls | Better fit | |
| The project is short-lived | Better fit | |
| You need many regions | Better fit |
Amanah TLC, our services beyond colocation, looks after everything around your rack. Pick only what you need; each service is ordered and billed on its own, and requests go through the customer portal.
10%
Bring a signed quote from another provider at 151 Front Street West and we beat it by 10%.
Need one boundary around several racks, or a room of your own? It is planned with you and priced by quote.
Your racks behind a mesh cage of your own, for teams whose auditors want physical separation.
A partitioned suite of your own for larger deployments, with power planned per rack, up to 30 kW.
Just need two or three racks? Each one is added at the standard rates, in the same building.
Still deciding? Call sales on ext. 1, see every price, compare private racks or read how to choose a provider in Toronto.
With colocation you own the hardware and we house it, power it, cool it and connect it. If you would rather not buy servers, we supply them in the same building as dedicated servers, on their own or alongside your colocation.
Count the rack units your servers take up; one U is 1.75″ tall. For a few servers, a shared rack priced by the U is the simplest start. Past 5 U, a quarter rack costs less and gives you your own lockable door. Find your size shows the plan for your U count.
At 110V, 1A is about 110 W and 20A is about 2.2 kW. A shared rack includes 1A per U; quarter and half racks include 20A, and a full rack includes two 20A circuits, about 4.4 kW. Add up what your servers draw under load, not the rating on the power supply. If you need more, power upgrades are on the Pricing page, and dense racks go up to 30 kW.
The monthly price pays for the space, the power and cooling, physical security, the bandwidth in your plan and the people who run the building. Our prices are published, so you can see what each size costs before you call.
Bring them in yourself, or ship them to us and our remote hands team racks and cables them. Your rack is ready for your equipment by the next business day after you sign.
Yes. Start with one server in a shared rack, then move to a quarter, half or full rack in the same building, on the same network, with the same team.
For several racks, we plan a private cage or a private suite with you, priced by quote. Power is planned per rack, up to 30 kW. Tell us what you need and we plan it with you.
Start with one U.
Grow to a full rack.
Tell us your U count and power draw, and we’ll size the right plan with you.